Matrix MiFare Classic Card Based Ultra Fast Door Controller, Time Attendance
₹35,000.00₹35,000.00×
RE-PS5 NAC Extender / Power Supply Panel
₹10,500.00
(-5%)The Power Supply unit is designed in such a way that it meets UL864 10th edition power limiting requirements and RE-PS5 shall be connected to any fire alarm control panel for 24VDC output. The Extended NAC power supply RE-PS5 is equipped 2 No’s of NAC outputs and 2 No’s of 24VDC outputs. These NAC outputs shall be activated respect to the NAC Follower Input or RS485 Input and NAC follower has the high priority. While connecting it AARAL through RS485, all the events of the RE-PS5 will be communicated to FACP and recorded as an event. Each NAC & 24VDC output in power supply RE-PS5 shall provide 24VDC @ 1.0 Amps maximum current.
The RE-PS5 is compact and cost-effective Power Supply in built charger. It provides power capabilities of existing notification appliance circuits and for other ancillary devices.
- Estimated delivery time 14-30 days
- 18 months warranty at Genuine Warranty Center.
- Whats in the box: charging cable and block
Product details
- Listed to UL 864 10th edition.
- Operates on 110 – 230 VAC.
- System ON, Mains and standby status indication.
- Standby battery backup built in charging.
- One remote alarm input.
- One Form-C Common fault relay.
- 2 No’s of 24VDC output short circuit protection.
- 2 No’s of NAC output short circuit protection.
- AC Loss Delay facility.
- Auto Silence facility.
- Trouble Reminder facility.
- All field wiring is power limited and supervised except battery and AC Input.
- Inbuilt Keys for Acknowledge & Restart.
- Ground fault detection facility @ 0 Ohms.
- Inbuilt RS 485 Bus communication.
- Addressing by 8 way DIP switch.
- System(field) Configurations using 8 way DIP switches.
Electrical Specification Mains Power 110 – 230 VAC, 60/50Hz Standby Power 24V DC (2 Nos of 12V, 65Ah (Max)) Sealed Lead acid battery
Panel enclosure can house up to 7Ah and for larger batteries UL listed battery box
should be used in three meters from the panel.Charging circuit Charging Voltage: 28 VDC
Charging current: 4.3 A
Charging Capacity: 65 AhOperating Condition Operating Temperature: 0oC to 49oC / 32 – 120oF.
Storage Temperature: 0 C to 60oC.
Relative Humidity: 93 ± 2% RH (non-condensing)Total Power Output 300W @ 230 VAC; 250W 110 VAC. Fault Relay Quantity: 1 No
Type: Form C
Contact Rating: 2A @30VDC
Power Factor: 1.0NAC Follower Input Quantity: 1 No
Wiring Style: Class B
Normal Operating Voltage: 16-33VDC
Signal trigger current: 5mA Max from FACPRemote Input Quantity: 1 No
Wiring Style: Class B
Normal Operating Voltage: 4 – 8 VDC
Signal trigger current: 3 mA (max)
Loop resistance: 40 Ω (max)
EOL: 4K7, ½ wattNAC Output Quantity: 2
Voltage: Regulated 24 VDC
Line Drop: 1.6 V
Total Current: 2.0 Max (1.0A each).
EOL: 4K7 ½W24VDC Output Quantity: 2
Wirng Style: Class B
Total Current: 2.0 Max (1.0A each).
Voltage: 24 VDCNetworking RS 485 Wire Size 2.5 Sq mm (#12 AWG) Max Mechanical Specification Dimension 400 W x 350 L x 102 D ( mm) Weight 8 Kg Max IP Rating IP50
General Inquiries